<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-30 12-32-32
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 71 dBuV YLEX
Pilot RDS Phase Difference
6.1 kHz 2.7 kHz 77 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 58 kHz 10468 0,2197
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,3 dBr 2,10 dBr 4,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 2 (Affairs) 0 1 1 1 12:32, 30.06.2025
RT
"EMMA & MATILDA - Sisko änen Halsey) "
AF EON
87.6 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 58 kHz MIN: 9 kHz % above 76 kHz: 0,2197 Acquired: 2025/06/30 12.31.29 Total samples: 10468 Equivalent time: 0:08:43 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 4,4 dBr MIN: 0,3 dBr AVE: 2,10 dBr % above 12,2 dBr: 0,0 Last value: 1,0 dBr (2025/06/30 12.31.28) 12.18 12.20 12.22 12.24 12.26 12.28 12.30 0 2 4 Pm [dBr]